Work out how much material fits in an e-beam crucible liner, and how much charge weight that represents. Use it before ordering pellets so the liner is filled to a workable level — not so little that the beam strikes the liner, not so much that the charge spills on melt.
— g charge
Liner volume — cm³ · usable volume — cm³
How the calculation works
| Liner volume | V = π × (Ø/2)² × depth — converted from mm to cm |
|---|---|
| Usable volume | Vusable = V × fill factor |
| Charge weight | m = Vusable × density |
Fill factor is the fraction of the liner depth occupied by melted charge. For e-beam liners, 60–80% is typical: below that the beam can strike the liner, above that the melt can spill or bridge. Pellets settle to roughly 55–65% of their bulk volume when melted, so a liner that looks full of pellets holds less metal than expected — always calculate by volume, not by eye.